Generator Sets for Sale: Models from 20 to 3,000 kW
Generator Sets for Sale: Models from 20 to 3,000 kW
If you are sourcing generator sets for sale in the UAE, start by matching the genset’s prime or standby rating to the way it will operate, then confirm the required frequency, voltage, engine configuration and installation format before requesting a quotation. Kaichen Power’s listed diesel models range from a 20 kW prime unit to a 3,000 kW prime unit, with examples covering several engine brands and power levels. The product information does not specify frequency or voltage for these models, so these must be confirmed for the selected configuration and project.
For procurement teams, distributors, EPC contractors and facility engineers, the model number alone is not enough to determine suitability. Compare the continuous project load with the relevant rating, account for the site’s operating profile, and verify the electrical and physical interface requirements before preparing a purchase specification.

Illustrative generator photo; exact enclosure, frequency and configuration may differ from the model discussed.
Generator sets for sale: sample models and ratings
The following diesel gensets illustrate the available range. Prime and standby ratings are stated separately; do not treat them as interchangeable. Dimensions and weights apply only to the specific models shown.
- KC-S20 — SDEC: 20 kW / 25 kVA prime; 22.0 kW / 27.5 kVA standby. Listed with four cylinders, 3.0 L displacement, fuel consumption of 200 g/kWh, dimensions of 1400×650×1100 mm and weight of 480 kg. Nine configurations are listed, with alternative engine models; confirm which configuration is being quoted.
- KC-P72.7 — Perkins: 72.7 kW / 90.9 kVA prime; 80.0 kW / 100.0 kVA standby. Engine model 1104D-E44TAG1; four cylinders and 4.4 L displacement. Listed dimensions are 1900×800×1200 mm and weight is 1200 kg.
- KC-D160 — Kaichen own engine: 160 kW / 200 kVA prime; 176.0 kW / 220 kVA standby. Engine model KCD8H217-G3; six cylinders and 8.27 L displacement. Listed dimensions are 2400×950×1380 mm and weight is 2000 kg.
- KC-C280-D — Cummins: 280 kW / 350 kVA prime; 308.0 kW / 385 kVA standby. Engine model QSZ10-G12, from Dongfeng Cummins; six cylinders and 9.9 L displacement. Listed dimensions are 2900×1200×1820 mm and weight is 3000 kg.
- KC-SG400 — Scania: 400 kW / 500 kVA prime; 440.0 kW / 550 kVA standby. Engine model DC13 507A 500; six cylinders and 12.7 L displacement. Listed dimensions are 3150×1300×1800 mm and weight is 2720 kg.
- KC-SG580 — Scania: 580 kW / 725 kVA prime; 638.0 kW / 797.5 kVA standby. Engine model DC16 078A 02-44; six cylinders and 16.4 L displacement. Listed dimensions are 3300×1300×2000 mm and weight is 5080 kg.
- KC-BDY1000 — mobile power vehicle: 1,000 kW / 1,250 kVA prime; 1,100.0 kW / 1,375 kVA standby. The listed engine and alternator combination is Yuchai YC6C1660-D31 + Leroy-Somer PMG 1000 kW. Dimensions are 11985×2550×3985 mm.
- KC-Y3000 — Yuchai: 3,000 kW / 3,750 kVA prime; 3,300.0 kW / 4,125 kVA standby. Two engine configurations are listed: YC16VC4900-D30 and YCC105TA4900-G30. Confirm the selected configuration. Listed dimensions are 7000×2800×3400 mm and weight is 22000 kg.
These are model-specific examples, not a complete specification for every possible build. For KC-S20, the listed engine models are alternatives rather than a combined engine package. The KC-Y3000 listing also presents alternative configurations. Ask for the exact quoted configuration and its corresponding technical documentation before comparing offers.

Illustrative generator photo; exact enclosure, frequency and configuration may differ from the model discussed.
Selecting a rating for the duty profile
First identify whether the genset will provide regular prime power or serve as a standby source. Compare the expected operating load with the rating for that duty, rather than sizing from the standby figure when the project needs regular operation. A procurement brief should describe typical and peak demand, expected operating hours and the loads that may run at the same time. Have the project engineer assess the required capacity against the actual load profile.
For facilities with equipment that starts in stages or has changing demand, include those operating conditions in the inquiry rather than relying only on the sum of nameplate loads. EPC teams should also coordinate the genset rating with the site electrical design and intended operating sequence. The product figures above provide model ratings; they do not establish suitability for an individual project.
Avoid applying fuel-consumption figures across the range. The listed values vary by model: for example, KC-P72.7 is listed at 208 g/kWh, KC-C280-D at 200 g/kWh, and both Scania examples at 192 g/kWh. These values belong to their respective product listings and should not be used as a general consumption estimate for another model or configuration. Request the applicable consumption information for the offered unit and expected load conditions.
Confirm frequency, voltage and installation details
Frequency and voltage are not specified in the individual product records shown here. They are essential selection details for a UAE project, so state the required values in the inquiry and request written confirmation against the exact model and configuration. Company information lists export support for 50/60 Hz and multiple voltage specifications, but this does not confirm the output of any specific genset in the range above.
Also confirm the installation format and interfaces needed for the project. Kaichen’s company information lists open-frame, soundproof, mobile-trailer, containerized, ATS and parallel product categories. It does not tie every category to every model in this article. Ask which format is available for the requested rating and what the offer includes. Where a mobile power vehicle is under consideration, clarify the complete supplied equipment and site access requirements.
For a UAE purchase, procurement documents should also identify the project location, indoor or outdoor arrangement, available space, access route and any site-specific environmental conditions. Ask the supplier to confirm which technical documents and certifications apply to the exact offered configuration and whether they meet the project’s requirements. Do not assume that a general export capability establishes compliance with a particular project specification.
Shortlist by load range, then verify the specific build
The examples provide reference points at 20, 72.7, 160, 280, 400, 580, 1,000 and 3,000 kW prime. A first shortlist can be based on the project’s required duty and capacity, but it should not replace engineering review. If a project is between listed ratings, request an appropriate proposal rather than assuming a model can be adjusted to a particular output.
Distributors can use the model and engine-brand information to identify options for a customer’s initial brief, while clearly marking frequency, voltage, configuration and installation format as items to confirm. EPC contractors can request a model-specific datasheet and electrical information for design review. Facility engineers can provide the expected load profile and backup or prime-use role to help the supplier recommend a suitable rating.
Kaichen Power’s company information also lists ATS automatic transfer, parallel systems and remote monitoring among its product or solution categories. Confirm their availability and scope for the particular model and project; they are not specified as standard equipment on the individual model records above.
Request a project-specific quotation
To compare generator sets for sale on a like-for-like basis, send the supplier the required prime or standby capacity, intended duty, frequency, voltage, preferred engine brand if applicable, installation format and project location. Include the load profile, space constraints and any required technical documentation. Ask for the exact engine configuration, model-specific dimensions and weight, applicable fuel-consumption data, included equipment, price, lead time, warranty terms, shipping scope and installation or service arrangements. These commercial and project details are not provided in the model data here and should be confirmed in the quotation.
Contact Kaichen Power at cnkcpower@gmail.com or +86-18012341322 with the project requirements and the model or rating under review. Request confirmation in writing of the output frequency and voltage, the exact configuration and any requirements specific to the UAE destination before purchase.
FAQ
What routine checks are recommended for a standby generator set?
Keep the room ventilated and dry, check oil, water and electrical items regularly, avoid prolonged overload operation, and run the genset periodically. The guidance recommends an unloaded test run of 5–10 minutes each week and a loaded test once a month where possible.
What should be checked if a generator set shuts down and will not restart?
Check the controller’s fault history first. If an overspeed, high-temperature or low-oil-pressure protection has activated, the protection may need to be manually reset. If there is no fault code, check the battery and fuel system.
How should a high coolant-temperature alarm be handled?
Reduce the load and let the genset run at idle until it cools, then stop it. Check coolant level, radiator blockage, fan-belt tension, thermostat, water pump and room ventilation. Do not add cold water while the system is hot; wait for it to cool before topping up.
Stay Updated with Our News